machine diagnosis instrument

MK-64 Online Vibrometer

Online vibrometer that accurately detects equipment abnormalities
Higher visibility with the new digital meter

POINT 1
Digital meter display for higher visibility
Enables checking of the signal level instantly.
POINT 2
Easy alarm setting with digital display
You can easily set any value in 1% units using the digital setting switch.
POINT 3
Level signal and alarm output functions
The vibrometer is equipped with level signal (4 to 20 mA DC) and alarm output (relay output).
POINT 4
Precise diagnosis available by connecting the portable diagnostic instrument
By connecting a MK-210HEII Vibration Data Management System, precise diagnosis, frequency analysis, and report output are made available.
POINT 5
Power source voltages for global application
MK-64 supports power source voltages ranging from 85 to 264 VAC for global application.

Applications

Continuous vibration monitoring of a motor, pump or fan
Collecting vibration data for a DCS
Equipment diagnosis for a rotating machine

Specifications

Sensor type Piezoelectric acceleration type 5.1 mV/(m/s2) (50 mV/G)
Measuring mode
range *
Measuring mode Measuring frequency Measuring range
Acceleration (RMS) 5 Hz to 20 kHz 5, 15, 50, 150, 500 m/s2
Acceleration (RMS) 1 kHz to 20 kHz 5, 15, 50, 150, 500 m/s2
Acceleration (PEAK) 1 kHz to 20 kHz 5, 15, 50, 150, 500 m/s2
Velocity (RMS) 5 Hz to 1 kHz 5, 15, 50, 150, 500 mm/s
Displacement (p-p) 5 Hz (or 15 Hz) to 1 kHz 50, 100, 200, 500, 1000 μm
Alarm 1 upper limit level for each measuring mode
Relay contact: 1a
Contact capacity: 20 W 110 VAC MAX.
Delay setting: 0 to 15 seconds
Signal output DC (level output)*: 4 to 200 mA DC, permissible load resistance 500 ΩMAX
AC (waveform output): Pickup signal through output 5.1 mV (m/s2)
Power source 85 to 264 VAC 50-60 Hz 10 W MAX.
Size 54(W) x 180(H) x 160(D) mm, mounting metal clip, excluding projections
Weight Approx. 890 g
Operating temperature range -10 to 60 °C (No condensation)

*Overall values (optional) are available for the operation method. Two measuring modes can be selected from five modes. (You can select two of the same mode and set two levels of alarms.)