Ministry of Land, Infrastructure, Transport and Tourism:
New Technology Information System(NETIS) Registration Number: KK-050041-A
HOME > Water, Environment Measuring Instruments >Ultrasonic Transit-Time Flowmeter > ATENAS Flow Measurement System
ATENAS Flow Measurement System for Rivers
ATENAS provides an optimal design for each application.
ATENAS provides the higher accuracy in irrigation management or in flood control.
ATENAS can be used as a continuous flow observation system during floods.


- Continuous flow measurement with high accuracy.

- Effects of suspended solids and pollution are minimized by an adoption of low-frequency ultrasonic transducers.

- The maximum applicable river width is 1000m, becouse of high-output ultrasonic transducers.

- SIMK (optional numerical hydroacoustic simulation) provides more accuracy even in floods.

- Options to meet various needs.
Typical Application

Common Speccifications
Signal processing units
| Type | KTT-200 | FTT-200 | FTT-28 |
|---|---|---|---|
| Applicable river (channel) width | 1m to 20m | 20m to 50m | 50m to 1,000m |
| Ultrasonic frequency | 200kHz | 200kHz | 28kHz |
| Rated RMS Power | 600W | 2kW | 2kW |
| Sensor placement | Max.8 acoustic paths /max. 2 channels |
Max. 8 acoustic paths(single- path on 8 levels, cross-path on 4 levels) | |
| Flow Velocity Range | -20m/s to +20m/s | -10m/s to +10m/s | |
| Data storage | Built-in data logger (standard: for 2 years with every 5 minute data gatherings) |
||
| Interface | VGA.Mouse/KB, USB×4, RS-232C×2, Ethernet×2 | ||
| Input | Water Level: analog inputs(4 to 20mA)×1, Reset: digital inputs×1 | ||
| Output | Flow Rate Water Level: analog outputs (4 to 20mA)×2 Flow Velocity: analog outputs(4 to 20mA)×each sensor level Alarm・Healthy : digital outputs×2 |
||
| Operation Environment | 0゚C to +50゚C (No condensation) |
5゚C to +35゚C (No condensation) |
|
| Power Supply | DC12V | AC100V to 240V±10%, 50/60Hz | |
Transducers
| Ultrasonic Transducer | TR-200/8 | TR-200/5 | TR-28/18 |
|---|---|---|---|
| Ultrasonic frequency | 200kHz | 200kHz | 28kHz |
| Rated RMS Power | 600W | 2kW | 2kW |
| Dimensions | φ70×h40mm | φ107×h68mm | φ183×h142mm |
| Weight | 1.3kg | 4.3kg | 8.4kg |
| Dimensions of hemisphere Protective Housing | φ218×h109mm | φ340×h170mm | φ440×h220mm |
Adpted site
Biwako / Seta-gawa Araizeki
| System | Cross path Responder system |
|---|---|
| Ultrasonicpath lengh | About 130m |
This system can measure continuously during floods.
Other adopted sites
| Customers | River | Sets |
|---|---|---|
| Ministry of Land Infrastructure,Transport and Tourism | Tone-gawa | 1 |
| Ministry of Land Infrastructure,Transport and Tourism | Kumano-gawa | 1 |
| Ministry of Land Infrastructure,Transport and Tourism | shinano-gawa | 2 |
| Ministry of Land Infrastructure,Transport and Tourism | Omaru-gawa | 1 |